Catheter design is a trade-off game. Pushability, torque control, kink resistance, lubricity, trackability and X-ray visibility all compete for the same wall thickness and lu...
READ MOREVagina gubernabilis est curvatio vaginae aptabilis distalis quae in vitro componi potest, ita ut vaginae extremitas ad diversos angulos patiente flecti possit. Hoc subtiliter ostendit et diversis anatomicis structuris accommodare potest.
commoda
| Steerable Vagina | ||||
| Type | Dimension | Angulus inclinatus | Materiae | Filum viverra |
| Unidirectional | 3.30 mm * 4.50 mm | 150° | Flexio sectionis: PEBAX2533; Transition section: PEBAX5533; Praecipua section: PA12 | Diver filum |
| 3.40 mm * 4.40 mm | 90° | PTFE Pebax3533/5533/7233 304 | Diver filum | |
| 3.80 mm * 5.40 mm | 150° | Flexio sectionis: PEBAX2533; Inflexio passiva sectio: PEBAX4033; Transition section: PEBAX5533; Praecipua section: PA12 TR55 | Diver filum | |
| 4.20 mm * 5.30 mm | 150° | Flexio sectionis: PEBAX2533; Transition section: PEBAX5533; Praecipua section: PA12 | Diver filum | |
| 4.30 mm * 5.30 mm | 90° | PTFE Pebax3533/5533 PA12 304 | Diver filum | |
| 4.40 mm * 5.40 mm | 120° | PTFE Pebax3533/5533/7233 304 | Diver filum | |
| 4.60 mm * 6.40 mm | 300° | Flexio sectionis: PEBAX3533; Transition section: PEBAX5533; Main section: PEBAX7233 | Diver filum | |
| 4.70 mm * 60.5 mm | 90° | Flexio sectionis: PEBAX3533; Transition section: PEBAX5533; Main section: PEBAX7233 | Diver filum | |
| 6.00 mm * 7.40 mm | 90° | Flexio sectionis: PEBAX3533; Praecipua section: PA12 TR55 | Diver filum | |
| 6.40 mm * 8.00 mm | 90° | PTFE Pebax3533/5533 PA12 304 | Diver filum | |
| Bidirectional | 2.60 mm * 2.70 mm | 180° | PTFE Pebax3533/5533 PA12 304 | Diver filum |
| 4.30 mm * 5.30 mm | 90° | PTFE Pebax3533/5533 PA12 304 | Diver filum | |
| 6.70 mm * 8.15 mm | 90° | Flexio sectionis: PEBAX4033; Transition section: PEBAX5533; Praecipua section: PA12 | Diver filum | |
| Quadridirectional | 2.15 mm * 2.85 mm | 180° | PTFE Pebax3533/5533 PA12 304 | LCP filum |
| 2.85 mm * 3.3 mm | 180° | PTFE Pebax3533/5533 PA12 304 | LCP filum | |
| 3.10 mm * 4.30 mm | 90° | Flexio sectionis: PEBAX2533; Transition section: PEBAX5533; Main section: PEBAX7233 | Diver filum | |
Vagina gubernabilis ad varias rationes medicas destinatur, incluso fibrillatione atriali catheterarum radiofrequentiae ablatio, chirurgiae urologicae, rationes bronchoscopicae, chirurgiae vasculariae et interventus neurovasculares, nec non biopsiae myocardiales. Vaginae gubernabilis munus magnum gerit in machinis medicorum regendis certis locis intra corpus humanum. Frequenter adhibetur in catheters electrophysiologiae cardiac, arteriae coronariae catheteri interveniendi, catheteri thrombectomi, et urologicae interventus machinae..
Catheter design is a trade-off game. Pushability, torque control, kink resistance, lubricity, trackability and X-ray visibility all compete for the same wall thickness and lu...
READ MORECum medicinae fabrica in corpore posita sit, prima quaestio non est: "Numquid operatur?" sed tutum est? Polyetheretherketone (PEEK) quaestionem illam per decades respondit. E...
READ MOREIs Medical PEEK Tubing Biocompatible MEDICA PEEK Tubing plerumque biocompatible cognoscitur et late in machinis quae contactum corporis requirunt, ob sta...
READ MOREVII Key Properties of Medical PI Tubing Engineers si Evaluate Medici PI Tubing artificio fabrum praecipue aestimatur pro coniunctione virtutis distrahent...