PTFE Etched Tube hoc praesertim in summus cura medicinae fabrica fabricandis cum cathetris cardiovascularibus, stents vascularibus et implantationibus ne...
READ MOREVagina gubernabilis est curvatio vaginae aptabilis distalis quae in vitro componi potest, ita ut vaginae extremitas ad diversos angulos patiente flecti possit. Hoc subtiliter ostendit et diversis anatomicis structuris accommodare potest.
commoda
| Steerable Vagina | ||||
| Type | Dimension | Angulus inclinatus | Materiae | Filum viverra |
| Unidirectional | 3.30 mm * 4.50 mm | 150° | Flexio sectionis: PEBAX2533; Transition section: PEBAX5533; Praecipua section: PA12 | Diver filum |
| 3.40 mm * 4.40 mm | 90° | PTFE Pebax3533/5533/7233 304 | Diver filum | |
| 3.80 mm * 5.40 mm | 150° | Flexio sectionis: PEBAX2533; Inflexio passiva sectio: PEBAX4033; Transition section: PEBAX5533; Praecipua section: PA12 TR55 | Diver filum | |
| 4.20 mm * 5.30 mm | 150° | Flexio sectionis: PEBAX2533; Transition section: PEBAX5533; Praecipua section: PA12 | Diver filum | |
| 4.30 mm * 5.30 mm | 90° | PTFE Pebax3533/5533 PA12 304 | Diver filum | |
| 4.40 mm * 5.40 mm | 120° | PTFE Pebax3533/5533/7233 304 | Diver filum | |
| 4.60 mm * 6.40 mm | 300° | Flexio sectionis: PEBAX3533; Transition section: PEBAX5533; Main section: PEBAX7233 | Diver filum | |
| 4.70 mm * 60.5 mm | 90° | Flexio sectionis: PEBAX3533; Transition section: PEBAX5533; Main section: PEBAX7233 | Diver filum | |
| 6.00 mm * 7.40 mm | 90° | Flexio sectionis: PEBAX3533; Praecipua section: PA12 TR55 | Diver filum | |
| 6.40 mm * 8.00 mm | 90° | PTFE Pebax3533/5533 PA12 304 | Diver filum | |
| Bidirectional | 2.60 mm * 2.70 mm | 180° | PTFE Pebax3533/5533 PA12 304 | Diver filum |
| 4.30 mm * 5.30 mm | 90° | PTFE Pebax3533/5533 PA12 304 | Diver filum | |
| 6.70 mm * 8.15 mm | 90° | Flexio sectionis: PEBAX4033; Transition section: PEBAX5533; Praecipua section: PA12 | Diver filum | |
| Quadridirectional | 2.15 mm * 2.85 mm | 180° | PTFE Pebax3533/5533 PA12 304 | LCP filum |
| 2.85 mm * 3.3 mm | 180° | PTFE Pebax3533/5533 PA12 304 | LCP filum | |
| 3.10 mm * 4.30 mm | 90° | Flexio sectionis: PEBAX2533; Transition section: PEBAX5533; Main section: PEBAX7233 | Diver filum | |
Vagina gubernabilis ad varias rationes medicas destinatur, incluso fibrillatione atriali catheterarum radiofrequentiae ablatio, chirurgiae urologicae, rationes bronchoscopicae, chirurgiae vasculariae et interventus neurovasculares, nec non biopsiae myocardiales. Vaginae gubernabilis munus magnum gerit in machinis medicorum regendis certis locis intra corpus humanum. Frequenter adhibetur in catheters electrophysiologiae cardiac, arteriae coronariae catheteri interveniendi, catheteri thrombectomi, et urologicae interventus machinae..
PTFE Etched Tube hoc praesertim in summus cura medicinae fabrica fabricandis cum cathetris cardiovascularibus, stents vascularibus et implantationibus ne...
READ MOREFlaring aut tipping medical PEEK Tubing praesertim fit per praecisionem scelerisque processus. Ob Polyethei aetheris ketonis punctum altissimum liquescens (circite...
READ MOREIn campis subtilitatis medicinae machinas et summus finis industrialis fabricatio, terminus superior resistentiae temperatus materialis saepe determinat de salute producti basel...
READ MOREIn recentioribus medicamentis intervenialibus minime incursivis; Micro Catheter nucleum instrumentum facti sunt medicis ut accessere minimas venas et cavitates in corpore...